Your bookmarks
Search
Menu

Compare products

Add your favorite products for comparison.

Share
Download all datasheets
Previous
Next
3 products
  • Category
    Kitchen, Public & Semi-public
  • Key features
    Hybrid, Battery-operated
  • Aerator Standard aerator
  • Connection Flexible inlet pipes
  • Electronic parts Autofocus infrared sensor, Solenoid valve, Light indicated function(s), Low battery indicator
  • Lever/Handle Two operating levers/handles, Easy-Grip surface
  • Mechanical parts Ceramic head part for flow control, Mixing valve for manual temperature control, Litter filter(s)
  • Advanced features Inner body made of DZR brass, Surfaces in contact with drinking water contain less than 0.3% lead, Waterways without nickel coating
  • Spout Swivel spout, Swivel range limiting option
  • Color Chrome
  • Additional features -
  • Diverter -
  • Number of spray functions -
  • Software settings
  • Afterflow period 4 s
  • Automatic flush off
  • Automatic flush period 30 s
  • Max. flow period 40 s
  • Flow attributes
  • Flow-rate at 300 kPa 0.2 l/s
  • Pressure loss with flow (0.2 l/s) 290 kPa
  • Technical properties
  • Backflow prevention (EN1717) AA
  • Connection size G3/8
  • Hot water supply max. +70°C
  • Material Brass/Plastic
  • Projection 193 mm
  • Working pressure 100 - 1000 kPa
  • DN-size (nominal dimension) -
  • Electronics
  • Battery AA 1.5 V Lithium x 2
  • Electrical Connection -
  • Regulations
  • EU Directives EMC Directive 2014/30/EU , RoHS Directive 2011/65/EU
  • EN standard EN 15091 , EN 817, ETSI EN 301 489-1 V1.9.2 , ETSI EN 300 328 v2.2.2 , EN 61000-6-1:2007 , EN 61000-6-3:2007+A1:2011+AC:2012 , EN 60335-1:2012+A11+A13+A1+A14+A2+A15:2021, Part 19.11.4
  • Noise class I (ISO 3822)
  • Protection class IP 54
  • Approvals and Declarations
  • Declaration of conformity EMC
  • Sintef Sintef Nr. 3083
  • STF EUFI29-20002662-TH2
  • KIWA SE 1462
  • UN38.3 UN38-3 Energizer L91
  • Category
    Kitchen, Health & Care, Public & Semi-public
  • Key features
    Hybrid, Plug transformer
  • Aerator Standard aerator
  • Connection Flexible inlet pipes
  • Electronic parts Autofocus infrared sensor, Solenoid valve, Power supply, Light indicated function(s)
  • Lever/Handle Two operating levers/handles, Easy-Grip surface
  • Mechanical parts Ceramic head part for flow control, Mixing valve for manual temperature control, Litter filter(s)
  • Advanced features Inner body made of DZR brass, Surfaces in contact with drinking water contain less than 0.3% lead, Waterways without nickel coating
  • Spout Swivel spout, Swivel range limiting option
  • Color Chrome
  • Additional features -
  • Diverter -
  • Number of spray functions -
  • Software settings
  • Afterflow period 4 s (2/4/8/10/20 s)
  • Automatic flush off (off/12/24/48/72 h)
  • Automatic flush period 30 s (10/30/60/120/180 s)
  • Max. flow period 40 s (10/40/60/120/180 s)
  • Flow attributes
  • Flow-rate at 300 kPa 0.2 l/s
  • Pressure loss with flow (0.2 l/s) 290 kPa
  • Technical properties
  • Backflow prevention (EN1717) AA
  • Connection size G3/8
  • Hot water supply max. +70°C
  • Material Brass/Plastic
  • Projection 193 mm
  • Working pressure 100 - 1000 kPa
  • DN-size (nominal dimension) -
  • Electronics
  • Battery -
  • Electrical Connection 230 / 5 V
  • Regulations
  • EU Directives Low Voltage Directive 2014/35/EU , EMC Directive 2014/30/EU , RoHS Directive 2011/65/EU
  • EN standard EN 200 , EN 15091, ETSI EN 301 489-1 V1.9.2 , ETSI EN 300 328 v2.2.2 , EN 61000-6-1:2007 , EN 61000-6-3:2007+A1:2011+AC:2012 , EN 60335-1:2012+A11+A13+A1+A14+A2+A15:2021, Part 19.11.4
  • Noise class I (ISO 3822)
  • Protection class IP 54 / transformer IP 20
  • Approvals and Declarations
  • Declaration of conformity LVD
  • Sintef Sintef Nr. 3083
  • STF EUFI29-20002662-TH2
  • KIWA SE 1462
  • UN38.3 -
  • Category
    Kitchen, Public & Semi-public
  • Key features
    Hybrid, Plug transformer
  • Aerator -
  • Connection Flexible inlet pipes
  • Electronic parts Autofocus infrared sensor, Solenoid valve, Power supply, Light indicated function(s)
  • Lever/Handle Easy-Grip surface, Two operating levers/handles
  • Mechanical parts Ceramic head part for flow control, Mixing valve for manual temperature control, Litter filter(s)
  • Advanced features Inner body made of DZR brass, Surfaces in contact with drinking water contain less than 0.3% lead, Waterways without nickel coating
  • Spout Swivel spout, Flexible model, Swivel range limiting option
  • Color Chrome
  • Additional features Soft- and Needle-Spray
  • Diverter Push operated diverter, Automatic reset
  • Number of spray functions 2 spray functions
  • Software settings
  • Afterflow period 4 s (2/4/8/10/20 s)
  • Automatic flush off (off/12/24/48/72 h)
  • Automatic flush period 30 s (10/30/60/120/180 s)
  • Max. flow period 40 s (10/40/60/120/180 s)
  • Flow attributes
  • Flow-rate at 300 kPa 0.2 l/s
  • Pressure loss with flow (0.2 l/s) 300 kPa
  • Technical properties
  • Backflow prevention (EN1717) AA
  • Connection size G3/8
  • Hot water supply max. +70°C
  • Material Brass/Plastic
  • Projection 200 mm
  • Working pressure 100 - 1000 kPa
  • DN-size (nominal dimension) DN15
  • Electronics
  • Battery -
  • Electrical Connection 230 / 5 V
  • Regulations
  • EU Directives Low Voltage Directive 2014/35/EU , EMC Directive 2014/30/EU , RoHS Directive 2011/65/EU
  • EN standard EN 15091, ETSI EN 301 489-1 V1.9.2 , ETSI EN 300 328 v2.2.2 , EN 61000-6-1:2007 , EN 61000-6-3:2007+A1:2011+AC:2012 , EN 60335-1:2012+A11+A13+A1+A14+A2+A15:2021, Part 19.11.4
  • Noise class I (ISO 3822) Oras lab.
  • Protection class IP 54 / transformer IP 20
  • Approvals and Declarations
  • Declaration of conformity LVD
  • Sintef -
  • STF EUFI29-20002662-TH2
  • KIWA SE 1628
  • UN38.3 -
3 products
  • Kitchen, Public & Semi-public
    Kitchen, Health & Care, Public & Semi-public
  • Key features
    Hybrid, Battery-operated
    Hybrid, Plug transformer
  • Aerator
    Standard aerator
    Standard aerator
  • Connection
    Flexible inlet pipes
    Flexible inlet pipes
  • Electronic parts
    Autofocus infrared sensor, Solenoid valve, Light indicated function(s), Low battery indicator
    Autofocus infrared sensor, Solenoid valve, Power supply, Light indicated function(s)
  • Lever/Handle
    Two operating levers/handles, Easy-Grip surface
    Two operating levers/handles, Easy-Grip surface
  • Mechanical parts
    Ceramic head part for flow control, Mixing valve for manual temperature control, Litter filter(s)
    Ceramic head part for flow control, Mixing valve for manual temperature control, Litter filter(s)
  • Advanced features
    Inner body made of DZR brass, Surfaces in contact with drinking water contain less than 0.3% lead, Waterways without nickel coating
    Inner body made of DZR brass, Surfaces in contact with drinking water contain less than 0.3% lead, Waterways without nickel coating
  • Spout
    Swivel spout, Swivel range limiting option
    Swivel spout, Swivel range limiting option
  • Color
    Chrome
    Chrome
  • Additional features
    -
    -
  • Diverter
    -
    -
  • Number of spray functions
    -
    -
  • Software settings
  • Afterflow period
    4 s
    4 s (2/4/8/10/20 s)
  • Automatic flush
    off
    off (off/12/24/48/72 h)
  • Automatic flush period
    30 s
    30 s (10/30/60/120/180 s)
  • Max. flow period
    40 s
    40 s (10/40/60/120/180 s)
  • Flow attributes
  • Flow-rate at 300 kPa
    0.2 l/s
    0.2 l/s
  • Pressure loss with flow (0.2 l/s)
    290 kPa
    290 kPa
  • Technical properties
  • Backflow prevention (EN1717)
    AA
    AA
  • Connection size
    G3/8
    G3/8
  • Hot water supply
    max. +70°C
    max. +70°C
  • Material
    Brass/Plastic
    Brass/Plastic
  • Projection
    193 mm
    193 mm
  • Working pressure
    100 - 1000 kPa
    100 - 1000 kPa
  • DN-size (nominal dimension)
    -
    -
  • Electronics
  • Battery
    AA 1.5 V Lithium x 2
    -
  • Electrical Connection
    -
    230 / 5 V
  • Regulations
  • EU Directives
    EMC Directive 2014/30/EU , RoHS Directive 2011/65/EU
    Low Voltage Directive 2014/35/EU , EMC Directive 2014/30/EU , RoHS Directive 2011/65/EU
  • EN standard
    EN 15091 , EN 817, ETSI EN 301 489-1 V1.9.2 , ETSI EN 300 328 v2.2.2 , EN 61000-6-1:2007 , EN 61000-6-3:2007+A1:2011+AC:2012 , EN 60335-1:2012+A11+A13+A1+A14+A2+A15:2021, Part 19.11.4
    EN 200 , EN 15091, ETSI EN 301 489-1 V1.9.2 , ETSI EN 300 328 v2.2.2 , EN 61000-6-1:2007 , EN 61000-6-3:2007+A1:2011+AC:2012 , EN 60335-1:2012+A11+A13+A1+A14+A2+A15:2021, Part 19.11.4
  • Noise class
    I (ISO 3822)
    I (ISO 3822)
  • Protection class
    IP 54
    IP 54 / transformer IP 20
  • Approvals and Declarations
  • Declaration of conformity
    EMC
    LVD
  • Sintef
    Sintef Nr. 3083
    Sintef Nr. 3083
  • STF
    EUFI29-20002662-TH2
    EUFI29-20002662-TH2
  • KIWA SE
    1462
    1462
  • UN38.3
    UN38-3 Energizer L91
    -