CategoryPublic & Semi-public
-
Key featuresTouchless, External transformer, Bidetta
-
Additional features 3, 6 and 9 meters photocell cables available: Oras No. 6105/3, 6105/6, 6105/9
-
Aerator Standard aerator
-
Electronic parts Infrared sensor, Power supply
-
Hand shower Bidetta hand shower
-
Lever/Handle Temperature control handle
-
Mechanical parts Mixing valve for manual temperature control, Non-return valve(s), Litter filter(s)
-
Number of spray functions 1 spray function
-
Shower parts Hand shower, Shower holder, Shower hose (1500 mm)
-
Spout Fixed spout, Casted construction
-
Color Chrome
-
Afterflow period 1 s (0-255 s)
-
Max. flow period 2 min (1 - 255 s)
-
Flow-rate at 300 kPa (with flow controller) 0.11 l/s
-
Pressure loss with flow (0.1 l/s) 220 kPa
-
Backflow prevention (EN1717) AA
-
Connection size G3/8
-
Hot water supply max. +70°C
-
Material Brass
-
Projection 120 mm
-
Working pressure 100 - 1000 kPa
-
Electrical Connection 230 VAC
-
EU Directives Low Voltage Directive 2014/35/EU , EMC Directive 2014/30/EU , RoHS Directive 2011/65/EU
-
EN standard EN 15091, ETSI EN 301 489-1 V1.9.2 , ETSI EN 300 328 v2.2.2 , EN 61000-6-1:2007 , EN 61000-6-3:2007+A1:2011+AC:2012 , EN 60335-1:2012+A11+A13+A1+A14+A2+A15:2021, Part 19.11.4
-
Noise class I (ISO 3822)
-
Protection class IP 67
-
Declaration of conformity LVD
-
STF EUFI29-22000144-TH5
Software settings
Flow attributes
Technical properties
Electronics
Regulations
Approvals and Declarations
-
CategoryHealth & Care
-
Key featuresTouchless, External transformer, Bidetta
-
Additional features -
-
Aerator Standard aerator
-
Electronic parts Infrared sensor, Power supply
-
Hand shower Bidetta hand shower
-
Lever/Handle Temperature control handle
-
Mechanical parts Litter filter(s), Non-return valve(s)
-
Number of spray functions 1 spray function
-
Shower parts Hand shower, Shower holder, Shower hose (1500 mm)
-
Spout Fixed spout
-
Color Chrome
-
Afterflow period 1 s (0-255 s)
-
Max. flow period 2 min (1 - 255 s)
-
Flow-rate at 300 kPa (with flow controller) 0.11 l/s
-
Pressure loss with flow (0.1 l/s) 220 kPa
-
Backflow prevention (EN1717) HC
-
Connection size Ø 10 mm
-
Hot water supply max. +70°C
-
Material Brass
-
Projection 120 mm
-
Working pressure 100 - 1000 kPa
-
Electrical Connection 230 VAC
-
EU Directives Low Voltage Directive 2014/35/EU , EMC Directive 2014/30/EU , RoHS Directive 2011/65/EU
-
EN standard EN 1113, EN 15091, ETSI EN 301 489-1 V1.9.2 , ETSI EN 300 328 v2.2.2 , EN 61000-6-1:2007 , EN 61000-6-3:2007+A1:2011+AC:2012 , EN 60335-1:2012+A11+A13+A1+A14+A2+A15:2021, Part 19.11.4
-
Noise class I (ISO 3822)
-
Protection class IP 67
-
Declaration of conformity LVD
-
STF -
Software settings
Flow attributes
Technical properties
Electronics
Regulations
Approvals and Declarations
2
products
Discontinued
Discontinued
-
Public & Semi-publicHealth & Care
-
Key featuresTouchless, External transformer, BidettaTouchless, External transformer, Bidetta
-
Additional features3, 6 and 9 meters photocell cables available: Oras No. 6105/3, 6105/6, 6105/9-
-
AeratorStandard aeratorStandard aerator
-
Electronic partsInfrared sensor, Power supplyInfrared sensor, Power supply
-
Hand showerBidetta hand showerBidetta hand shower
-
Lever/HandleTemperature control handleTemperature control handle
-
Mechanical partsMixing valve for manual temperature control, Non-return valve(s), Litter filter(s)Litter filter(s), Non-return valve(s)
-
Number of spray functions1 spray function1 spray function
-
Shower partsHand shower, Shower holder, Shower hose (1500 mm)Hand shower, Shower holder, Shower hose (1500 mm)
-
SpoutFixed spout, Casted constructionFixed spout
-
ColorChromeChrome
-
Afterflow period1 s (0-255 s)1 s (0-255 s)
-
Max. flow period2 min (1 - 255 s)2 min (1 - 255 s)
-
Flow-rate at 300 kPa (with flow controller)0.11 l/s0.11 l/s
-
Pressure loss with flow (0.1 l/s)220 kPa220 kPa
-
Backflow prevention (EN1717)AAHC
-
Connection sizeG3/8Ø 10 mm
-
Hot water supplymax. +70°Cmax. +70°C
-
MaterialBrassBrass
-
Projection120 mm120 mm
-
Working pressure100 - 1000 kPa100 - 1000 kPa
-
Electrical Connection230 VAC230 VAC
-
EU DirectivesLow Voltage Directive 2014/35/EU , EMC Directive 2014/30/EU , RoHS Directive 2011/65/EULow Voltage Directive 2014/35/EU , EMC Directive 2014/30/EU , RoHS Directive 2011/65/EU
-
EN standardEN 15091, ETSI EN 301 489-1 V1.9.2 , ETSI EN 300 328 v2.2.2 , EN 61000-6-1:2007 , EN 61000-6-3:2007+A1:2011+AC:2012 , EN 60335-1:2012+A11+A13+A1+A14+A2+A15:2021, Part 19.11.4EN 1113, EN 15091, ETSI EN 301 489-1 V1.9.2 , ETSI EN 300 328 v2.2.2 , EN 61000-6-1:2007 , EN 61000-6-3:2007+A1:2011+AC:2012 , EN 60335-1:2012+A11+A13+A1+A14+A2+A15:2021, Part 19.11.4
-
Noise classI (ISO 3822)I (ISO 3822)
-
Protection classIP 67IP 67
-
Declaration of conformityLVDLVD
-
STFEUFI29-22000144-TH5-
Software settings
Flow attributes
Technical properties
Electronics
Regulations
Approvals and Declarations