Compare products
Add your favorite products for comparison.
Share
Download all datasheets
Previous
Next
2
products
-
CategoryWashbasin, Public & Semi-public
-
Key featuresBattery-operated, Touchless
-
Aerator PCA® - constant flow rate regardless of pressure variations, Standard aerator
-
Connection Flexible inlet pipes
-
Electronic parts Autofocus infrared sensor, Solenoid valve, Low battery indicator
-
Lever/Handle Temperature control handle
-
Mechanical parts Mixing valve for manual temperature control, Non-return valve(s), Litter filter(s)
-
Advanced features Convertible for cold or premixed-water supply
-
Spout Fixed spout, Casted construction
-
Color Chrome
-
Temperature Temperature preset fixable
-
Afterflow period 2 s ± 1 s
-
Max. flow period 2 min
-
Automatic flush -
-
Automatic flush period -
-
Flow-rate at 300 kPa (with flow controller) 0.10 l/s
-
Pressure loss with flow (0.1 l/s) 200 kPa
-
Backflow prevention (EN1717) AA
-
Connection size G3/8
-
Hot water supply max. +70°C
-
Material Brass
-
Projection 96 mm
-
Working pressure 100 - 1000 kPa
-
Battery Lithium 2CR5 6 V
-
Bluetooth version -
-
EU Directives EMC Directive 2014/30/EU , RoHS Directive 2011/65/EU
-
EN standard EN 15091, ETSI EN 301 489-1 V1.9.2 , ETSI EN 300 328 v2.2.2 , EN 61000-6-1:2007 , EN 61000-6-3:2007+A1:2011+AC:2012 , EN 60335-1:2012+A11+A13+A1+A14+A2+A15:2021, Part 19.11.4
-
Noise class I (ISO 3822)
-
Protection class IP 55
-
Declaration of conformity EMC
-
Sintef Sintef Nr. 1534
-
STF EUFI29-21002459-TH1
-
KIWA SE 1821
-
UN38.3 UN38-3 Maxell 2CR5
Software settings
Flow attributes
Technical properties
Electronics
Regulations
Approvals and Declarations
-
CategoryPublic & Semi-public, Housing
-
Key featuresTouchless, Bluetooth®, Battery-operated
-
Aerator PCA® - constant flow rate regardless of pressure variations, Standard aerator
-
Connection Flexible inlet pipes
-
Electronic parts Autofocus infrared sensor, Solenoid valve, Low battery indicator
-
Lever/Handle Temperature control handle, Long shape
-
Mechanical parts Non-return valve(s), Litter filter(s)
-
Advanced features Software settings adjustable via App, Convertible for cold or premixed-water supply
-
Spout Fixed spout, Casted construction
-
Color Chrome
-
Temperature Temperature preset fixable
-
Afterflow period 3 s (1-20 s)
-
Max. flow period 2 min (1 - 1800 s)
-
Automatic flush off (off/1-120 h)
-
Automatic flush period 30 s (1-1800 s)
-
Flow-rate at 300 kPa (with flow controller) 0.1 l/s
-
Pressure loss with flow (0.1 l/s) 200 kPa
-
Backflow prevention (EN1717) AA
-
Connection size G3/8
-
Hot water supply max. +70°C
-
Material Brass
-
Projection 96 mm
-
Working pressure 100 - 1000 kPa
-
Battery Lithium 2CR5 6 V
-
Bluetooth version 4.x (D034445)
-
EU Directives Radio Equipment Directive 2014/53/EU , Low Voltage Directive 2014/35/EU , EMC Directive 2014/30/EU , RoHS Directive 2011/65/EU
-
EN standard EN 15091, ETSI EN 301 489-1 V1.9.2 , ETSI EN 300 328 v2.2.2 , EN 61000-6-1:2007 , EN 61000-6-3:2007+A1:2011+AC:2012 , EN 60335-1:2012+A11+A13+A1+A14+A2+A15:2021, Part 19.11.4
-
Noise class I (ISO 3822)
-
Protection class IP 55
-
Declaration of conformity RED
-
Sintef -
-
STF -
-
KIWA SE 1821
-
UN38.3 UN38-3 Maxell 2CR5
Software settings
Flow attributes
Technical properties
Electronics
Regulations
Approvals and Declarations
2
products
Discontinued
Discontinued
Bluetooth
-
Washbasin, Public & Semi-publicPublic & Semi-public, Housing
-
Key featuresBattery-operated, TouchlessTouchless, Bluetooth®, Battery-operated
-
AeratorPCA® - constant flow rate regardless of pressure variations, Standard aeratorPCA® - constant flow rate regardless of pressure variations, Standard aerator
-
ConnectionFlexible inlet pipesFlexible inlet pipes
-
Electronic partsAutofocus infrared sensor, Solenoid valve, Low battery indicatorAutofocus infrared sensor, Solenoid valve, Low battery indicator
-
Lever/HandleTemperature control handleTemperature control handle, Long shape
-
Mechanical partsMixing valve for manual temperature control, Non-return valve(s), Litter filter(s)Non-return valve(s), Litter filter(s)
-
Advanced featuresConvertible for cold or premixed-water supplySoftware settings adjustable via App, Convertible for cold or premixed-water supply
-
SpoutFixed spout, Casted constructionFixed spout, Casted construction
-
ColorChromeChrome
-
TemperatureTemperature preset fixableTemperature preset fixable
-
Afterflow period2 s ± 1 s3 s (1-20 s)
-
Max. flow period2 min2 min (1 - 1800 s)
-
Automatic flush-off (off/1-120 h)
-
Automatic flush period-30 s (1-1800 s)
-
Flow-rate at 300 kPa (with flow controller)0.10 l/s0.1 l/s
-
Pressure loss with flow (0.1 l/s)200 kPa200 kPa
-
Backflow prevention (EN1717)AAAA
-
Connection sizeG3/8G3/8
-
Hot water supplymax. +70°Cmax. +70°C
-
MaterialBrassBrass
-
Projection96 mm96 mm
-
Working pressure100 - 1000 kPa100 - 1000 kPa
-
BatteryLithium 2CR5 6 VLithium 2CR5 6 V
-
Bluetooth version-4.x (D034445)
-
EU DirectivesEMC Directive 2014/30/EU , RoHS Directive 2011/65/EURadio Equipment Directive 2014/53/EU , Low Voltage Directive 2014/35/EU , EMC Directive 2014/30/EU , RoHS Directive 2011/65/EU
-
EN standardEN 15091, ETSI EN 301 489-1 V1.9.2 , ETSI EN 300 328 v2.2.2 , EN 61000-6-1:2007 , EN 61000-6-3:2007+A1:2011+AC:2012 , EN 60335-1:2012+A11+A13+A1+A14+A2+A15:2021, Part 19.11.4EN 15091, ETSI EN 301 489-1 V1.9.2 , ETSI EN 300 328 v2.2.2 , EN 61000-6-1:2007 , EN 61000-6-3:2007+A1:2011+AC:2012 , EN 60335-1:2012+A11+A13+A1+A14+A2+A15:2021, Part 19.11.4
-
Noise classI (ISO 3822)I (ISO 3822)
-
Protection classIP 55IP 55
-
Declaration of conformityEMCRED
-
SintefSintef Nr. 1534-
-
STFEUFI29-21002459-TH1-
-
KIWA SE18211821
-
UN38.3UN38-3 Maxell 2CR5UN38-3 Maxell 2CR5
Software settings
Flow attributes
Technical properties
Electronics
Regulations
Approvals and Declarations